TA-Modulator
Product branding

Features and Benefits
Precise temperature control
Provide uniquely shaped EQM characteristic for best modulating control.
Precise control
Uniquely shaped EQM characteristic provides an up to 6 times larger operating stroke than linear valves.
Quick hydronic balancing
Automatic flow limitation when actuator is fully open protects entire system against overflows.
Easy troubleshooting
Flow and differential pressure measuring helps to reduce pump consumption and provides all necessary data for system diagnostics.
Applications
Heating and cooling systems.
Functions
Control EQM: DN 15 low flow, DN 10-200 normal flow
Control LIN: DN 65-200 high flow
Differential pressure control
Isolation (for use during system maintenance – see "Leakage rate")
Measuring (ΔH, t, q)
Pre-setting (max. flow)
Pressure class [PN]
DN 10-32: PN 16
DN 40-50: PN 25
DN 65-200: PN 16, PN 25
Flow range
DN 10: 17 - 120 l/h
DN 15 LF: 38 - 230 l/h
DN 15: 92 - 480 l/h
DN 20: 200 - 975 l/h
DN 25: 340 - 1750 l/h
DN 32: 720 - 3600 l/h
DN 40: 1000 - 6500 l/h
DN 50: 2150 - 11200 l/h
DN 65: 4150 - 24100 l/h
DN 65 HF: 7460 - 36500 l/h
DN 80: 5850 - 37300 l/h
DN 80 HF: 9520 - 49000 l/h
DN 100: 11700 - 51700 l/h
DN 100 HF: 18000 - 75900 l/h
DN 125: 15000 - 77300 l/h
DN 125 HF: 23300 - 127000 l/h
DN 150: 26100 - 126000 l/h
DN 150 HF: 38800 - 190000 l/h
DN 200: 35000 - 209000 l/h
DN 200 HF: 73200 - 329000 l/h
qmax = l/h at each setting and fully open valve plug.
LF = Low flow
HF = High flow,
Temperature
DN 10-25 with Δp insert in PPS, DN 40-50: Max. working temperature: 90°C; Min. working temperature: -10°C
DN 10-32: Max. working temperature: 120°C, Min. working temperature: -20°C
DN 40-50: Max. working temperature: 90°C, Min. working temperature: -10°C
DN 65-200: Max. working temperature: 120°C, Min. working temperature: -10°C
Media
Water or neutral fluids, water-glycol mixtures (0-57%).
Characteristics
DN 65-200 HF: Linear
Independent shaped EQM.
Leakage rate
Leakage flow ≤ 0.01% of max. q, max (max. setting) and correct flow direction. (Class IV according to EN 60534-4).
Lift
DN 10-20: 4 mm
DN 150: 30 mm
DN 200: 32,5 mm
DN 25-32: 6,5 mm
DN 40-50: 15 mm
DN 65-125: 20 mm
Rangeability
DN 100-150: > 150
DN 100-150 HF: > 125
DN 10-15 LF: > 50
DN 15-32: > 75
DN 200: > 125
DN 200 HF: > 125
DN 40-80: > 125
Actuators
*) Adapter to be ordered separately, see "Adapters for actuators".
DN 100-125 HF: TA-Slider 750 ΔpV ≤ 4 bar, TA-Slider 1600 ΔpV ≤ 8 bar.
DN 10-20: TA-Slider 160, EMO TM, TA-TRI.
DN 150-200, DN 150-200 HF: TA-Slider 1600.
DN 25-32: TA-Slider 160, TA-TRI, TA-MC50-C*.
DN 40-50: TA-Slider 500, TA-Slider 750*.
DN 65-125: TA-Slider 750.
For more details on actuators, see separate technical leaflets.
TA-Slider 160, 500, 750 and 1600 also available with fail-safe function.
Connection
DN 10-50: External thread according to ISO 228.
DN 65-200: Flanges according to EN-1092-2, type 21. Face to face length according to EN 558, series 1.
Connection to actuator
DN 10-32: M30x1.5, push
DN 40-50: M30x1.5, push/pull
DN 65-200: 2xM8, push/pull
Material
Valve body: AMETAL®
Valve insert: AMETAL® and PPS
Valve plug: Brass CW724R (CuZn21Si3P)
Spindle: Stainless steel
Spindle seal: EPDM O-ring
Δp insert: PPS and AMETAL® or PPS
Membrane: EPDM
Springs: Stainless steel
O-rings: EPDM
DN 40-50:
Valve body: AMETAL®
Valve insert: AMETAL®
Valve plug: AMETAL® and PTFE
Spindle: Stainless steel
Spindle seal: EPDM O-ring
Δp insert: PPS
Membrane: EPDM
Springs: Stainless steel
O-rings: EPDM
DN 65-200:
Valve body: Ductile iron EN-GJS-400-15
Valve insert: Ductile iron EN-GJS-400-15 and brass
Valve plug: Stainless steel and EPDM O-ring
Valve seat: Aluminium bronze
Spindle: Stainless steel
Spindle seal: EPDM
Δp insert: Ductile iron EN-GJS-400-15, stainless steel and brass.
Membrane: Reinforced EPDM, DN 200 EPDM
Springs: Stainless steel
O-rings: EPDM
AMETAL® is the dezincification resistant alloy of IMI.
Surface treatment
DN 10-50: Non treated
DN 65-200: Electrophoretic painting
Certifications and directives
EAC
*) Notified body.
CE 0409*: PN 25 DN 150-200.
CE: PN 16 DN 65-200, PN 25 DN 65-125.