Pressure independent balancing and control valve (PIBCV)

The pressure-independent balancing and control valve TA-Nano Plus ensures optimum performance over a long life. Adjustable maximum flow enables design flow and eliminates overflows for accurate hydronic control. The TA-Nano Plus together with our balancing instruments enables advanced measuring and diagnostics. 

Technical SpecificationsTA-Nano_TA-Nano_Plus_EN_low.pdf

Product branding

imi_ta

Features and Benefits

Smallest PIBCV in the market fitting within the most constrained area

Slim and compact shape simplifies installation.

Precise hydronic balancing

Smoothly adjustable setting of max. flow prevents over flow through terminal unit.

Full control of the system

Exact flow measuring and unique diagnostic functions for ultimate energy savings and highly reliable system.

Precise setting and ease of commissioning

Valve position visible when actuator is mounted, easy valve identification with colour coding. High reliability High resistance to corrosion using AMETAL®, strong resistance to dirt and completely tight valve.

Applications

Heating and cooling systems.

Functions

Control

Differential pressure control

Isolation (for use during system maintenance – see "Leakage rate")

Measuring (ΔH, t, q)

Pre-setting (max. flow)

Flushing

Dimensions

DN 10-25

Pressure class [PN]

PN 25

Differential pressure (ΔpV)

Max. differential pressure (ΔpVmax):

600 kPa = 6 bar

Min. differential pressure (ΔpVmin):

DN 10 NF/15 LF/15 NF: 15 kPa = 0.15 bar

DN 15 HF: 20 kPa = 0.20 bar

DN 20 NF: 18 kPa = 0.18 bar

DN 20 HF: 30 kPa = 0.30 bar

DN 25 NF: 25 kPa = 0.25 bar

(Valid for position 10, fully open. Other positions will require lower differential pressure, check with the software HySelect.)

ΔpVmax = The maximum allowed pressure drop over the valve to fulfill all stated performances.

ΔpVmin = The minimum recommended pressure drop over the valve, for proper differential pressure control.

Flow range

The flow (qmax) can be set within the range:

DN 10 NF: 19 - 190 l/h

DN 15 LF: 29 - 290 l/h

DN 15 NF: 55 - 550 l/h

DN 15 HF: 105 - 1050 l/h

DN 20 NF: 110 - 1100 l/h

(DN 20 HF: 160 - 1600 l/h)

(DN 25 NF: 220 - 2200 l/h)

qmax = l/h at each setting and fully open valve plug.

LF = Low flow

NF = Normal flow

HF = High flow

Temperature

Max. working temperature: 120°C

Min. working temperature: -10°C

Media

Water or neutral fluids, water-glycol mixtures (0-57%).

Characteristics

Linear, best suited for on/off control

Leakage rate

(Class VI according to EN 60534-4).

Tight sealing

Lift

4 mm

Actuators

See separate technical documentation on EMO T, EMO TM, TA-TRI and TA-Slider 160.

Marking

IMI, PN, DN and flow direction arrow. Insert: TA-Nano, DN (+LF/NF/HF)

LF: Red insert.

NF: White insert.

HF: Grey insert.

Connection

External thread according to ISO 228.

Internal thread according to ISO 7

Connection to actuator

M30x1.5

Material

Valve body: AMETAL®

Valve insert: AMETAL® and PPS

Valve plug: PPS

Spindle: Stainless steel

Spindle seal: EPDM O-ring

Δp insert: Brass CW614

Membrane: EPDM

Springs: Stainless steel

O-rings: EPDM

Setting wheel: PA

Measuring points: AMETAL®

Sealings: EPDM Caps: Polyamide and TPE

AMETAL® is the dezincification resistant alloy of IMI.

The table below assists you in finding the relevant product based on its variant. For more details, please download the datasheet above.