Skip to main content
TA-Slider 160 BACnet/Modbus

TA-Slider 160 BACnet/Modbus

Digitally configurable proportional push actuator for Bus communication with BACnet MS/TP or Modbus RTU – 160/200 N

Digitally configurable actuators for Bus communication with BACnet MS/TP or Modbus RTU, with or without change-over. A wide range of setup options provide extensive flexibility for on-site parameter adaptation. Fully programmable binary input, relay and adjustable max. stroke of the valve bring new opportunities for advanced hydronic control and balancing.

Technical SpecificationsTA-Slider_160_BACnet_Modbus_EN_low.pdf

Product branding

imi_ta

Features and Benefits

Convenient, reliable setup

Fully customisable by smartphone via Bluetooth using a TA-Dongle.

Fully configurable

More than 200 setup options allow input and output signals, binary input, relay, characteristics and many other parameters to be configured.

Easy diagnostics

Tracks the last 10 errors to allow system faults to be found quickly.

Quick copying of settings

Setup configuration can be copied quickly from the TA-Dongle to identical TA-Slider actuators.

Temperature

Max. medium temperature: 120°C

Operating environment: 0°C – +50°C (5-95%RH, non-condensing)

Storage environment: -20°C – +70°C (5-95%RH, non-condensing)

Control speed

10 s/mm

Supply voltage [V]

24 VAC/VDC ±15%. Frequency 50/60 Hz ±3 Hz. BACnet/Modbus CO: 24 VAC only for enabling powering of TA-M106 actuator.

Power consumption

BACnet/Modbus:

Operation: < 1.5 VA (VAC); < 1.0 W (VDC)

Standby: < 1.2 VA (VAC); < 0.75 W (VDC)

BACnet/Modbus CO:

Operation: < 1.5 VA (VAC)

Standby: < 1.2 VA (VAC)

TA-M106 actuator consumption must be added separately.

Input signal

0(2)-10 VDC, Ri 47 kΩ.

0.33 Hz low pass filter.

Adjustable hysteresis sensitivity 0.1-0.5 VDC.

By BACnet/Modbus or with hybrid control mode

Default setting: By BACnet/Modbus. If Hybrid mode chosen, default input signal is Proportional 0-10 VDC.

Proportional: 0-10, 10-0, 2-10 or 10-2 VDC.

Proportional dual-range (for change-over): 0-3.3 / 6.7-10 VDC, 2-4.7 / 7.3-10 VDC, 0-4.5 / 5.5-10 VDC or 2-5.5 / 6.5-10 VDC.

Proportional split-range: 0-5, 5-0, 5-10 or 10-5 VDC; 0-4.5, 4.5-0, 5.5-10 or 10-5.5 VDC; 2-6, 6-2, 6-10 or 10-6 VDC.

Output signal

BACnet/Modbus

Stroke

6,9 mm

Automatic detection of the valve lift (stroke detection)

Noise level

Max. 30 dBA

Marking

Label: IMI TA, CE, product name, article No. and technical specification.


Colour

White RAL 9016, grey RAL 7047.

Adjusting force

160/200 N

Self-adjusting for IMI valves.

Connection to valve

Swivelling nut M30x1,5

Cable

Separate overmoulded cables (see Additional equipment).

Type LiYCY 5x0.34 mm2 (cables A and B) and type LiYY 6x0.34 mm2 (cable C).

Halogen free, fire class B2ca – s1a, d1, a1 according to EN 50575.

Relay cable (CO version):

Type LiYY 3x0.34 mm2.

1, 2 or 5 m. With connector to actuator TA-M106.

Halogen free, fire class B2ca – s1a, d1, a1 according to EN 50575.

Material

Cover: PC/ABS GF8

Housing: PA GF40.

Swivelling nut: Nickel-plated brass.

Ingress protection

IP54 all directions (according to EN 60529)

Protection class

III (SELV)

(according to EN 61140)

Certifications and directives

EMC-D. 2014/30/EU: EN 60730-1, -2-14.

LV-D. 2014/35/EU: EN 60730-1, -2-14.

RoHS-D. 2011/65/EU: EN 63000

The table below assists you in finding the relevant product based on its variant. For more details, please download the datasheet above.

Related products