TA-Smart
Product branding

Features and Benefits
Best-in-class control
Accurate and fast control response even at very low flows in common part load conditions. Ensures full modulating control for the complete operating stroke leading to world class control and efficiencies.
Optional cloud connection
Easy remote access to data and configuration parameters allows to verify and adjust system performance.
Optional ΔT and temperature return limitation
Optimize the efficiency of your production units by ensuring optimal temperature regimes.
Change-over functionality
Possibility to switch between two operating conditions to manage seasonality or heating and cooling with the same valve in change-over applications.
High measurement accuracy
High flow and temperature measurement accuracies in all configurations (medium type, and temperature) for all flow regimes.
Compactness and limited number of components
Reduces installation time and space requirements facilitating retrofit installation.
Convenient, reliable setup
Fully customizable and commissionable using Bluetooth enabled smart device reducing commissioning and diagnostic time.
Easy diagnostics
Continuous measurement (flow, temperature, power...) enables accurate error identification in system hydronics.
Versatility in communication
Digital (key Bus protocols and MQTT) and Analog (0(2)-10 VDC or 0(4)-20 mA).
Applications
Heating and cooling systems.
Functions
Control (flow, power, position)
Pre-setting (max./min. flow, max. power, max./min. position)
Reading (flow, power, energy, supply/return temperature, ΔT, position)
Change-over
Delayed start-up
ΔT and temperature return limitation
Diagnostic/Logging
Error safe position
Manual override
Mode, status and position indication
Valve blockage protection
Valve clogging detection
Wireless
Thread
Bluetooth Low Energy (BLE)
Pressure class [PN]
DN 15-50: PN 25
DN 65-125: PN 16, PN 25
Differential pressure (ΔpV)
Flow range
Temperature
Max. working temperature: 110°C
Min. working temperature: -10°C
Operating environment: 0°C – +50°C (5-95%RH, non-condensing)
Storage environment: -20°C – +70°C (5-95%RH, non-condensing)
Media
Water or neutral fluids, water-glycol mixtures (0-57%).
Supply voltage [V]
24 VAC/VDC ±15%. Frequency 50/60 Hz ±3 Hz
Power consumption
Input signal
By BACnet/Modbus or Analog signal. Analog in VDC or mA, selectable by jumper in the SmartBox;
Proportional dual-range (for change-over): 0-4.5 / 5.5-10 VDC. 2-5.5 / 6.5-10 VDC. 0-3.3 / 6.7-10 VDC. 2-4.7 / 7.3-10 VDC. 0-9 / 11-20 mA. 4-11 / 13-20 mA.
0(2)-10 VDC, Ri 47 kΩ.
0(4)-20 mA R i 500 Ω.
Adjustable sensitivity 0.1-0.5 VDC; 0.33 Hz low pass filter.
Default setting: Proportional 0-10 VDC
Proportional: 0-10, 10-0, 2-10 or 10-2 VDC; 0-20, 20-0, 4-20 or 20-4 mA
Proportional split-range: 0-5, 5-0, 5-10 or 10-5 VDC; 0-4.5, 4.5-0, 5.5-10 or 10-5.5 VDC; 2-6, 6-2, 6-10 or 10-6 VDC; 0-10, 10-0, 10-20 or 20-10 mA; 4-12, 12-4, 12-20 or 20-12 mA
Output signal
0(2)-10 VDC, max. 8 mA, min. 1.25 kΩ.
BACnet/Modbus
Characteristics
Settable: Stepless between EQM 0.25 and inverted EQM 0.25.
Flow control accuracy
±10% from 0.5% to 4% of qnom
±5% from 4% to 100% of qnom
Measurement accuracy
Leakage rate
DN 15-50: Leakage rate < 0.01% of q, nom with correct flow direction (Class IV according to EN 60534-4)
DN 65-125: Tight sealing with correct flow direction (Class V according to EN 60534-4)
Pipe connection
DN 15-50: External thread according to ISO 228.
DN 65-125: Flanges according to EN-1092-2, type 21. Face to face length according to EN 558, series 1.
Temperature sensor cable
10 m halogen free cable on request.
DN 15-50: 3 m halogen free
DN 65-125: 5 m halogen free
Material
Surface treatment
DN 15-50: Non treated
DN 65-125: Electrophoretic painting
Ingress protection
IP54 (according to EN 60529)
Protection class
(according to EN 61140)
Certifications and directives
EMC-D. 2014/30/EU: EN 60730-1, -2-14.
PED: 2014/68/EU
Product standards EN 60730-x.
CAD_2D_3D_STEP
The table below assists you in finding the relevant product based on its variant. For more details, please download the datasheet above.
Art. No. |
---|