Vento Connect
For heating, solar, and chilled water systems
Vento Connect is a cyclonic vacuum degasser for heating and solar systems, and chilled water systems. Its use is particularly recommended where high performance, compact design and precision are required. The industrial version VI is especially designed for high pressure applications up to 20.5 bar. The new BrainCube Connect control panel allows a new level of connectivity, enabling communication with the BMS system, other BrainCubes as well as remote operation of the pressurisation system through live viewing.
Features and Benefits
Higher Efficiency Cyclonic vacuum degassing
Significantly higher efficiency than most other vacuum degassing systems.
Direct degassing of make-up water
For additional protection against corrosion.
Easy Commissioning, Remote Access and Trouble-shooting
Integrated standard connections to our IMI Webserver and to BMS.
Vento Compact
Compact design for floor and wall hanging installation
Optional sound absorbing wall bracket
For Vento Compact in installations particularly sensitive to structure-borne sound.
Full range
Serving installations from 0,5 - 20,5 bar
Applications
For systems according to EN 12828, SWKI HE301-01, EN 12976, ENV 12977, EN 12952, EN 12953
Heating, solar and chilled water systems.
Supply voltage [V]
1 x 230 V (± 10 %) / 50 Hz
Transportation and storage
In frostless, dry places
Media
Ethylene or propylene glycol-based antifreeze up to 50%.
Non-aggressive and non-toxic system media.
Pressure
Max. admissible pressure, PS: see Articles
Min. admissible pressure, PSmin: -1 bar
Standard
Constructed according to MD 2006/42/EC, Annex II 1.A EMC-D. 2014/30/EU
Temperature
Max. admissible temperature, TS: 90°C
Min. admissible temperature, TSmin: +5 °C
Enclosure class
IP54 according to EN 60529
Mechanical connections
Sin1: inlet from the system G1/2"
Sout: outlet to the system G1/2"
Sin1: inlet from the system G3/4"
Sout: outlet to the system G3/4"
Swm: inlet water make-up G3/4"
Material
Metal components with medium contact: carbon steel, cast iron, stainless steel, AMETAL®, brass, gunmetal.
Electrical connection
Onsite fuses according to power demand and local norms
4 (V/VI) or 3 (VF) potential-free outputs (NO) for external alarm indication (230V max. 2A)
1 RS 485 In/Output
1 Ethernet RJ45 plug socket
1 USB Hub plug socket
Art. No. |
---|