Zeparo G-Force

Zeparo G-Force

Microbubble, dirt and magnetite separator with Cyclonic technology

Comprehensive range of products for sludge and magnetite separation in heating and cooling water systems. The number of potential applications as well as their modular construction is unique. Its new cyclonic technology takes dirt separation efficiency to the next level.
Technical SpecificationsZeparo_G-Force_EN_low.pdf

Product branding

imi_pneumatex

Features and Benefits

High separation efficiency with Cyclonic technology

Cleans your system in fewer cycles, each time reducing dirt particles that would normally deposit in the system with each additional cycle. The dirt collected can be easily and quickly flushed out with the help of the drain valve.

High efficiency independent of dimension

Separation efficiency increases together with flow velocity. The pressure drop remains stable regardless of the amount of dirt collected. Even higher protection for higher flows, e.g. in cooling applications. Suitable for heating and cooling installations.

Cleans and protects the installation

Protects critical investments such as boilers, pumps, valves, chillers, and calorie meters, from dirt-related malfunction and failure. No risk of clogging - the dirt collected can be easily and quickly flushed out with the help of the drain valve. Reduces maintenance and associated costs over entire system lifetime.

Magnet Accessory

Optimizes separation efficiency even further for sludge and magnetite (black iron oxide) deposits that consist of finer magnetic particles. Easy handling and cleaning.

Air separation

Due to the cyclonic effect, pressure in the centre of the device is below system pressure, causing more air bubbles to be released than in standard separators. The air is concentrated in the centre forming larger bubbles, which can raise in the upper section of the G-Force where there is less flow. This function requires an additional ZUTX automatic air vent.

Applications

Heating and chilled water systems.

Pressure

Max. admissible pressure, PS: see Articles

Min. admissible pressure, PSmin: 0 bar

Temperature

Max. admissible temperature, TS: PN16: 110°C

Max. admissible temperature, TS: PN25: 180°C

Min. admissible temperature, TSmin: -10 °C

Media

Ethylene or propylene glycol-based antifreeze up to 50%.

Non-aggressive and non-toxic system media.

Transportation and storage

In dry places

Marking

Body: flow direction arrow.

Label: DN, PN, tsmax and tsmin.

Connection

Flanges PN 16 according to EN 1092-1.

Grooved ends.

Welding ends.

Material