Multilux 4-F-Set

Multilux 4-F-Set

For radiator two point bottom connection R1/2 or G3/4 with an additional connection for floor heating

For connection radiators with a bottom connection and floor heating is used to control the room temperature and for limitation of the return temperature. Centre-to centre distance of connection is 50 mm. Installation in angle type. Both thermostatic inserts include the V-exact II precision presetting with 8 stepless presetting values.

Technical SpecificationsMultilux-4-F-Set_EN_lq.pdf

Product branding

imi_heimeier

Features and Benefits

Combination of thermostatic valve and return temperature limiter

For bath or designer radiators and additional underfloor heating

Shut-off barriers to radiators and underfloor heating

for maintenance without interrupting operation

Elegant covers

White RAL 9016

V-exact II presetting for hydronic balancing

For radiators and floor heating circuit

Applications

Floor heating systems

Two-pipe heating systems

Functions

Individual room temperature control.

Maximum limitation of the floor heating return temperature.

Presetting (V-exact II) at thermostatic valve and return temperature limiter.

Shut-off

Dimension [DN]

DN 15

Size (DN)

15

Pressure class [PN]

PN 10

Temperature

Max. working temperature: 90°C

Min. working temperature: 2°C.

Connection to thermostatic head

M30x1.5, RTL with additional adaptor

Marking

THE, RTL and II+ Designation. Flow direction arrows. White protection caps.
H = Supply heating system
HR = Return heating system
F = Supply floor heating
FR = Return floor heating

Colour (for Varianting)

White (RAL 9016)

Radiator connection

Radiator connection: Adapters for R1/2 and G3/4, for radiator connections. Tolerance compensation ±1,0 mm with special union nuts and flexible flat seal system for installation free of tension.

Pipe connection

G3/4 external thread for compression fittings for plastic, copper, precision steel or multi-layer pipe.

Material

Valve body: Corrosion resistant Gunmetal.
O-rings: EPDM rubber
Valve disc: EPDM rubber
Return spring: Stainless steel
Valve insert: Brass, PPS (polyphenylsulphide) and SPS (syndiotactic polystyrene)
The complete thermostatic insert can be replaced using the fitting tool without draining the system.
Spindle: Niro-steel spindle with double O-ring sealing. The outer O-ring can be replaced under pressure.
Cover: ABS

Surface treatment

Valve body gunmetal, fittings are nickel-plated.

3rd Item Number

9690-57.800

Austria_ABK_number

381H39A