Skip to main content
TA-SCOPE

TA-SCOPE

Balancing instrument

TA-SCOPE is a tough, effective balancing instrument for measuring and documenting of differential pressure, flow, temperature and power in hydronic systems. Robust, accurate and easy-to-use, TA-SCOPE delivers quicker, more cost-efficient balancing and enables rapid troubleshooting. TA-SCOPE links effortlessly to the HySelect PC software gaining the maximum benefit from recorded data and enabling professional report writing and automatic software upgrades.
Technical SpecificationsTA-SCOPE_EN_MAIN.pdf
Technical SpecificationsTA-SCOPE_PL_low.pdf

Product branding

imi_ta

Features and Benefits

User-friendly design

Ergonomic and custom designed user-interface ensures easy and more comfortable balancing.

Interactive software

Step by step software wizards for measuring, balancing and trouble shooting ensure a fast commissioning process.

Wireless communication

For reliable balancing, a fully charged TA-SCOPE provides three days of power-efficient wireless performance.

DpS-Visio

The Dp Sensor has an OLED display for showing Dp measurement, temperature and status. It also has an automatic flushing and calibration function.

Functions

Differential Pressure Sensor unit – the DpS-Visio communicates wirelessly with the Handheld and has an OLED display for showing its status, measured data and other information.

TA-SCOPE is a balancing instrument for measuring and documenting of differential pressure (Δp), flow, temperature and power in hydronic systems.

TA-SCOPE automatically performs calibration when needed. The design of the sensor unit and a short flow-through during calibration eliminate measurement errors caused by insufficient venting of the measuring device.

TA-SCOPE consists of two main components: Handheld unit – computer-based unit programmed with the TA valve characteristics. Straightforward functions with easy-to-follow instructions on the colour display.

Temperature

<0.2°C, Temperature liquid medium measurement: -20°C – +120°C

*) Do not leave water in the sensor when there is a risk of freezing.

Ambient temperature for the instrument: During operation and charging: 0°C – +40°C

Ambient temperature for the instrument: During storage*: -20°C – +60°C

Battery capacity, operating and charge times

Handheld unit:
- battery capacity: 4 400 mAh
- operating time (with backlight on): >25 h
- charge time to full capacity: 6-7 h

DpS-Visio (Dp sensor unit):
- battery capacity: 1 400 mAh
- operating time (continuous measurements): >25 h
- charge time to full capacity: 2.5 h
Logging time (in sleep mode): >100 days

Charger

Input voltage: 100-240 VAC

Case dimensions

TA-SCOPE case: LxWxH = 335x290x150 mm

TA-SCOPE Premium case: LxWxH = 426x290x159 mm

Humidity

Ambient humidity: max. 90%RH

Ingress protection

Handheld unit (in wireless mode): IP64

Measurement range

Total pressure: TA-SCOPE max. 1 600 kPa TA-SCOPE HP max. 2 500 kPa Differential pressure: TA-SCOPE 0 - 500 kPa TA-SCOPE HP 0 - 1 000 kPa Recommended pressure range during flow measurements: TA-SCOPE 1 - 500 kPa TA-SCOPE HP 3 - 1 000 kPa

Measurement deviation

Flow: as for differential pressure + valve deviation

TA-SCOPE 0.1 kPa or 1% of reading, whichever is the highest

TA-SCOPE HP 0.2 kPa or 1% of reading, whichever is the highest

Temperature: <0.2°C

The table below assists you in finding the relevant product based on its variant. For more details, please download the datasheet above.