![TA-Slider 500](/_next/image?url=https%3A%2F%2Fcdn.tessa.imihy.eimed-project.de%2F554792%2FWeb_placeholder%2Fta-slider_500_left.webp&w=3840&q=75)
TA-Slider 500
Digitally configurable proportional push-pull actuator – 500/300 N
Digitally configurable actuators with a wide range of setup options provide extensive flexibility for on-site parameter adaptation. Fully programmable binary input, relay and adjustable max. stroke of the valve bring new opportunities for advanced hydronic control and balancing.
Product branding
![imi_ta](/_next/image?url=https%3A%2F%2Fcdn.tessa.imihy.eimed-project.de%2F615293%2FLogo_IMI_TA_Purple.png&w=640&q=75)
Features and Benefits
Convenient, reliable setup
Fully customisable by smartphone via Bluetooth using a TA-Dongle.
Fully configurable
More than 200 setup options allow input and output signals, binary input, relay, characteristics and many other parameters to be configured.
Easy diagnostics
Tracks the last 10 errors to allow system faults to be found quickly.
Quick copying of settings
Setup configuration can be copied quickly from the TA-Dongle to identical TA-Slider actuators.
Temperature
Operating environment: 0°C – +50°C (5-95%RH, non-condensing)
Storage environment: -20°C – +70°C (5-95%RH, non-condensing)
Control speed
4 or 6 s/mm.
Default setting: 4 s/mm.
Supply voltage [V]
24 VAC/VDC ±15%., Frequency 50/60 Hz ±3 Hz., CO version: , 24 VAC ±15%., Frequency 50/60 Hz ±3 Hz
Power consumption
Standby: 1.3 VA (VAC); 0.6 W (VDC)
I/O version:
Operation: 3.6 VA (VAC); 1.7 W (VDC)
Standby: 1.3 VA (VAC); 0.6 W (VDC)
Plus version:
Operation: 4.0 VA (VAC); 1.9 W (VDC)
Standby: 1.3 VA (VAC); 0.6 W (VDC)
Input signal
0(2)-10 VDC, Ri 47 kΩ.
Adjustable hysteresis sensitivity 0.1-0.5 VDC; 0.33 Hz low pass filter.
Default setting: Proportional 0-10 VDC
Proportional: 0-10, 10-0, 2-10 or 10-2 VDC.
Proportional dual-range (for change-over): 0-3.3 / 6.7-10 VDC, 10-6.7 / 3.3-0 VDC, 2-4.7 / 7.3-10 VDC or 10-7.3 / 4.7-2 VDC.
Proportional split-range: 0-5, 5-0, 5-10 or 10-5 VDC; 0-4.5, 4.5-0, 5.5-10 or 10-5.5 VDC; 2-6, 6-2, 6-10 or 10-6 VDC.
Output signal
Default setting: Proportional 0-10 VDC
I/O, Plus versions: 0(2)-10 VDC, max. 8 mA, min. 1.25 kΩ.
Ranges: See “Input signal”.
Stroke
16,2 mm
Automatic detection of the valve lift (stroke detection)
Noise level
Max. 30 dBA
Marking
Label: IMI TA, CE, product name, article No. and technical specification.,
Colour
White RAL 9016, grey RAL 7047.,
Adjusting force
Pull 300 N
Push 500 N
Connection to valve
Swivelling nut M30x1,5
Cable
Halogen free as option, fire class B2ca – s1a, d1, a1 according to EN 50575.
TA-Slider 500: type LiYY, 3x0.25 mm2.
TA-Slider 500 I/O: type LiYY, 5x0.25 mm2.
TA-Slider 500 Plus: type LiYY, 5x0.25 mm2 and relay cable type H03VV-F, 3x0.75 mm2.
Ingress protection
IP54 all directions (according to EN 60529)
Protection class
(according to EN 61140)
III TA-Slider 500, 500 I/O (SELV)
II TA-Slider 500 Plus (protective insulation)
Certifications and directives
EMC-D. 2014/30/EU: EN 60730-1, -2-14.
LV-D. 2014/35/EU: EN 60730-1, -2-14.
RoHS-D. 2011/65/EU: EN 63000
Art. No. |
---|