TA-Slider 750 Fail-safe T-2T

TA-Slider 750 Fail-safe T-2T

Digitally configurable proportional push-pull actuator with electronic fail-safe function and temperature measurement capability – 750 N

Digitally configurable fail-safe actuators with temperature

measurement capability for all control systems for all control systems

with or without change-over. To be mounted on a PIBCV for tackling

ΔT syndrome or for handling change-over based on T supply or ΔT

sign detection. Wide range of setup possibilities gives high flexibility

to adapt parameters on-site. Fully programmable binary input, relay

and adjustable max. stroke of the valve bring new opportunities for advanced hydronic control and balancing.

Technical SpecificationsTA-Slider_750_Fail-safe_T-2T_EN_low.pdf

Product branding

imi_ta

Features and Benefits

Optional ΔT and temperature return limitation
Optimize the efficiency of your production units by ensuring optimal temperature regimes.

Change-over functionality
Switch between heating/cooling flows according to input signal or automatically using T supply or ΔT sign detection.

Fully configurable fail-safe
Setting of stroke position (extended, retracted or intermediate position) and delay feature for entering/leaving failsafe mode for a reliable and optimal fail-safe function.

Convenient, reliable setup
Fully customisable by smartphone via Bluetooth using a TA-Dongle.

Fully configurable
More than 200 setup options allow input and output signals, binary input, relay, characteristics and many other parameters to be configured.

Easy diagnostics
Tracks the last 10 errors to allow system faults to be found quickly and health check of fail-safe function.

Functions

3-point control

Automatic change-over function

Delayed start-up

ΔT and temperature return limitation

Diagnostic/Logging

Electronic fail-safe function

Error safe position

Manual override

Minimum stroke setting

Mode, status and position indication

On-off control

Output signal VDC

Proportional control

Reading (supply/return temperature, ΔT, position)

Stroke detection

Stroke limitation setting

Valve blockage protection

Valve clogging detection

Temperature

Media temperature: 0°C – +120°C

Operating environment: 0°C – +50°C (5-95%RH, non-condensing)

Storage environment: -20°C – +50°C (5-95%RH, non-condensing)

Absolute temperature

PT1000 Class AA: ±0.1°C at 0°C

PT1000 Class B: ±0.3°C at 0°C

Control speed

3, 4, 6, 8, 12 or 16 s/mm

Default setting: 3 s/mm

Supply voltage [V]

24 VAC/VDC ±15%. Frequency 50/60 Hz ±3 Hz

Power consumption

Peak: < 18.4 VA (VAC); < 9.1 W (VDC)
Operation: < 9 VA (VAC); < 4.8 W (VDC)
Standby: < 1.6 VA (VAC); < 0.7 W (VDC)
Peak consumption occurs for a short period after a power cut for recharging
capacitors.

Input signal

0(2)-10 VDC, Ri 47 kΩ.

0(4)-20 mA R i 500 Ω.

Adjustable sensitivity 0.1-0.5 VDC; 0.33 Hz low pass filter.

Default setting: Proportional 0-10 VDC

Proportional dual-range (for change-over): 0-3.3 / 6.7-10 VDC, 10-6.7 / 3.3-0 VDC, 2-4.7 / 7.3-10 VDC or 10-7.3 / 4.7-2 VDC.

Proportional: 0-10, 10-0, 2-10 or 10-2 VDC; 0-20, 20-0, 4-20 or 20-4 mA

Proportional split-range: 0-5, 5-0, 5-10 or 10-5 VDC; 0-4.5, 4.5-0, 5.5-10 or 10-5.5 VDC; 2-6, 6-2, 6-10 or 10-6 VDC; 0-10, 10-0, 10-20 or 20-10 mA; 4-12, 12-4, 12-20 or 20-12 mA

Output signal

0(2)-10 VDC, max. 8 mA, min. 1.25 kΩ.

0(4)-20 mA, max. 700 Ω.

Default setting: Proportional 0-10 VDC

Ranges: See “Input signal”.

Characteristics

Default setting: Linear.

Linear, EQM 0.25 and inverted EQM 0.25.

Measurement accuracy

Temperature pocket: Class AA
In valve measuring point: Class B
Surface mounted: Class B

Time constant τ (63%)

In valve measuring point: 5s

Surface mounted: 20s

Temperature pocket: 9s

Stroke

22 mm

Automatic detection of the valve lift (stroke detection)

Noise level

Max. 40 dBA

Marking

IMI TA, product name, article No. and technical specification.
LED indication description.

Colour

Orange RAL 2011, grey RAL 7043.

Adjusting force

750 N

Connection to valve

By two M8 screws to the valve and by quick connection to the stem

Temperature sensor cable

Halogen free, fire class IEC 60332-3-24 (cat. C).

Cable

Wire cross-section*: 0.5-2.0 mm2
Protection class I: H05VV-F or similar
Protection class III: LiYY or similar
*) Note: Wire cross-sections must be chosen according to actuator power consumption and line length, such as the voltage supply to the actuator does not go below 20.4 VAC/VDC (24 VAC/VDC minus 15%).
In case of VDC input signal on a 24 VAC/VDC powered actuator, the voltage drop on neutral line must be smaller than the defined hysteresis level for the VDC input signal.

Material

Cover: PBT
Bracket: Alu EN44200

Ingress protection

IP54 all directions (according to EN 60529)

Protection class

(according to EN 61140)

Class I

Weight

1,6 kg

Certifications and directives

EMC-D. 2014/30/EU: EN 60730-1, -2-14.

LV-D. 2014/35/EU: EN 60730-1, -2-14.

RoHS-D. 2011/65/EU: EN 63000