TA-Smart-Dp
Features and Benefits
Precise and stable differential pressure control
Delivers desired differential pressure ensuring accurate balancing.
Optional cloud connection
Easy remote access to data and configuration parameters allows to verify and adjust system performance.
High measurement accuracy
High flow and temperature measurement accuracies in all configurations (medium type, and temperature) for all flow regimes.
Compactness and limited number of components
Reduces installation time and space requirements facilitating retrofit installation.
Convenient, reliable setup
Fully customizable and commissionable using Bluetooth enabled smart device reducing commissioning and diagnostic time.
Easy diagnostics
Continuous measurement (flow, temperature, power...) enables accurate error identification in system hydronics.
Versatility in communication
Digital (key Bus protocols and MQTT) and Analog (0(2)-10 VDC or 0(4)-20 mA).
Applications
Heating and cooling systems.
Functions
Reading (flow, power, energy, supply/return temperature, ΔT, position)
Differential pressure control
Measuring (ΔpL)
Pre-setting Δp over the load (ΔpL)
Supply voltage [V]
24 VAC/VDC ±15%. Frequency 50/60 Hz ±3 Hz
Ingress protection
IP54 (according to EN 60529)
Media
Water or neutral fluids, water-glycol mixtures (0-57%).
Wireless
Thread
Bluetooth Low Energy (BLE)
Temperature
Max. working temperature: 110°C
Min. working temperature: -10°C
Operating environment: 0°C – +50°C (5-95%RH, non-condensing)
Storage environment: -20°C – +70°C (5-95%RH, non-condensing)
Input signal
By BACnet/Modbus
Leakage rate
DN 15-50: Leakage rate < 0.01% of q, nom with correct flow direction (Class IV according to EN 60534-4)
DN 65-125: Tight sealing with correct flow direction (Class V according to EN 60534-4)
Output signal
0(2)-10 VDC, max. 8 mA, min. 1.25 kΩ.
BACnet/Modbus
Pressure class [PN]
DN 15-50: PN 25
DN 65-125: PN 16, PN 25
Dp sensor
18-33 VDC or 24 VAC +15/-10 % (0-10 V)
Pipe connection
DN 15-50: External thread according to ISO 228.
DN 65-125: Flanges according to EN-1092-2, type 21. Face to face length according to EN 558, series 1.
Protection class
(according to EN 61140)
Surface treatment
DN 15-50: Non treated
DN 65-125: Electrophoretic painting
Dp sensor
Min. working temperature: -15°C
Operating environment: -15°C – +80°C (5-95%RH, non-condensing)
Max. working temperature: 80°C
Storage environment: -40°C – +80°C (5-95%RH, non-condensing)
Temperature sensor cable
10 m halogen free cable on request.
DN 15-50: 3 m halogen free
DN 65-125: 5 m halogen free
Certifications and directives
EMC-D. 2014/30/EU: EN 60730-1, -2-14.
Dp sensor: CE certification EN 61326-2-3.
PED: 2014/68/EU
Product standards EN 60730-x.
Material
Flow range
Power consumption
Measurement accuracy
Differential pressure (ΔpV)
Art. No. |
---|