Skip to main content
Simply Compresso

Simply Compresso

For heating systems up to 400 kW and cooling systems up to 600 kW

Simply Compresso is a precision pressurisation system with a compressor and integrated expansion vessels for heating, solar and chilled water systems. Especially suitable in situations where extreme compactness, plug&play installation and full pressure control are required. Simply Compresso is the latest addition to the Compresso Connect series intended for 4 bar safety valve installations up to 400 kW in heating capacity. The BrainCube Connect control panel ensures a new level of connectivity, enabling communication with the BMS system and other BrainCubes, as well as remote operation of the pressurisation system through live viewing.

Technical SpecificationsAccessories_EN_low.pdf
Technical SpecificationsPlanning_and_Calculation_EN_low.pdf
Technical SpecificationsSimply_Compresso_EN_low.pdf

Product branding

imi_pneumatex

Features and Benefits

Improved design for easier and more comfortable operation

Resistant 3.5" TFT illuminated colour touch display. Intuitive and user friendly menu. Web based interface with remote control and live view. BrainCube Connect control panel integrated into TecBox.

State-of-the-Art Connectivity

Standard connections (RS485, Ethernet, USB) to BMS and remote devices, saving time during commissioning and maintenance, and allowing for control of the unit.

Plug & Play installation and start-up

Getting the Simply Compresso up and running only takes three easy steps.

Pressure maintenance with ECO-night mode

Keeping compressor runtime to the absolute minimum.

Applications

For systems according to EN 12828, SWKI HE301-01, solar systems according to EN 12976, ENV 12977, with on-site excess temperature protection in case of power outage.

Heating and cooling systems.

Pressure

Max. admissible pressure, PS: 4 bar

Max. working pressure, dpu max: 3,5 bar

Min. admissible pressure, PSmin: 0 bar

Min. working pressure, dpu min: 0,5 bar

Temperature

Max. admissible temperature, TSmax: 70°C

Min. admissible temperature, TSmin: +5 °C

Max. admissible bag temperature, TB: 70°C

Min. admissible bag temperature, TBmin: 5°C

Media

Ethylene or propylene glycol-based antifreeze up to 50%.

Non-aggressive and non-toxic system media.

Supply voltage [V]

1 x 230V (-6% + 10%) / 50/60 Hz

Electric load

See Articles

Accuracy

Precision pressure maintenance ±0,1 bar

Expansion vessel

Primary vessel included in TecBox. For more information see Technical description - Expansion vessels.

For PED purposes

Min. admissible temperature, TSmin: -10°C

Max. admissible temperature, TS: 120°C

Transportation and storage

In frostless, dry places

Standard

Constructed according to MD 2006/42/EC, Annex II 1.A EMC-D. 2014/30/EU

Material

Main materials include steel, brass, and bronze.
Steel. Color beryllium.
Airproof butyl bag according to EN 13831.

Enclosure class

IP 22 according to EN 60529

The table below assists you in finding the relevant product based on its variant. For more details, please download the datasheet above.