Skip to main content
TA-Modulator

TA-Modulator

Pressure independent balancing and control valve for modulating control

The uniquely shaped EQM characteristics provide highly precise temperature control. The valve is compatible with linear, proportional or 3-point actuators. A built-in differential pressure controller provides high control authority, control stability and automatic limitation of design flow. Measurement of flow and available pressure enables system optimisation and diagnostics.

Technical SpecificationsTA-Modulator_EN_low.pdf

Product branding

imi_ta

Features and Benefits

Precise temperature control

Provide uniquely shaped EQM characteristic for best modulating control.

Precise control

Uniquely shaped EQM characteristic provides an up to 6 times larger operating stroke than linear valves.

Quick hydronic balancing

Automatic flow limitation when actuator is fully open protects entire system against overflows.

Easy troubleshooting

Flow and differential pressure measuring helps to reduce pump consumption and provides all necessary data for system diagnostics.

Applications

Heating and cooling systems.

Functions

Control EQM: DN 15 low flow, DN 10-200 normal flow

Control LIN: DN 65-200 high flow

Differential pressure control

Isolation (for use during system maintenance – see "Leakage rate")

Measuring (ΔH, t, q)

Pre-setting (max. flow)

Pressure class [PN]

DN 10-32: PN 16

DN 40-50: PN 25

DN 65-200: PN 16, PN 25

Flow range

The flow (qmax) can be set within the range:
DN 10: 17 - 120 l/h
DN 15 LF: 38 - 230 l/h
DN 15: 92 - 480 l/h
DN 20: 200 - 975 l/h
DN 25: 340 - 1750 l/h
DN 32: 720 - 3600 l/h
DN 40: 1000 - 6500 l/h
DN 50: 2150 - 11200 l/h
DN 65: 4150 - 24100 l/h
DN 65 HF: 7460 - 36500 l/h
DN 80: 5850 - 37300 l/h
DN 80 HF: 9520 - 49000 l/h
DN 100: 11700 - 51700 l/h
DN 100 HF: 18000 - 75900 l/h
DN 125: 15000 - 77300 l/h
DN 125 HF: 23300 - 127000 l/h
DN 150: 26100 - 126000 l/h
DN 150 HF: 38800 - 190000 l/h
DN 200: 35000 - 209000 l/h
DN 200 HF: 73200 - 329000 l/h
qmax = l/h at each setting and fully open valve plug.
LF = Low flow
HF = High flow

Temperature

DN 10-25 with Δp insert in PPS, DN 40-50: Max. working temperature: 90°C; Min. working temperature: -10°C

DN 10-32: Max. working temperature: 120°C, Min. working temperature: -20°C

DN 40-50: Max. working temperature: 90°C, Min. working temperature: -10°C

DN 65-200: Max. working temperature: 120°C, Min. working temperature: -10°C

Media

Water or neutral fluids, water-glycol mixtures (0-57%).

Characteristics

DN 65-200 HF: Linear

Independent shaped EQM.

Leakage rate

Leakage flow ≤ 0.01% of max. q, max (max. setting) and correct flow direction. (Class IV according to EN 60534-4).

Lift

DN 10-20: 4 mm

DN 150: 30 mm

DN 200: 32,5 mm

DN 25-32: 6,5 mm

DN 40-50: 15 mm

DN 65-125: 20 mm

Rangeability

DN 100-150: > 150

DN 100-150 HF: > 125

DN 10-15 LF: > 50

DN 15-32: > 75

DN 200: > 125

DN 200 HF: > 125

DN 40-80: > 125

Actuators

*) Adapter to be ordered separately, see "Adapters for actuators".

DN 100-125 HF: TA-Slider 750 ΔpV ≤ 4 bar, TA-Slider 1600 ΔpV ≤ 8 bar.

DN 10-20: TA-Slider 160, EMO TM, TA-TRI.

DN 150-200, DN 150-200 HF: TA-Slider 1600.

DN 25-32: TA-Slider 160, TA-TRI, TA-MC50-C*.

DN 40-50: TA-Slider 500, TA-Slider 750*.

DN 65-125: TA-Slider 750.

For more details on actuators, see separate technical leaflets.

TA-Slider 160, 500, 750 and 1600 also available with fail-safe function.

Connection

DN 10-50: External thread according to ISO 228.

DN 65-200: Flanges according to EN-1092-2, type 21. Face to face length according to EN 558, series 1.

Connection to actuator

DN 10-32: M30x1.5, push

DN 40-50: M30x1.5, push/pull

DN 65-200: 2xM8, push/pull

Material

DN 10-32:

Valve body: AMETAL®

Valve insert: AMETAL® and PPS

Valve plug: Brass CW724R (CuZn21Si3P)

Spindle: Stainless steel

Spindle seal: EPDM O-ring

Δp insert: PPS and AMETAL® or PPS

Membrane: EPDM

Springs: Stainless steel

O-rings: EPDM

DN 40-50:

Valve body: AMETAL®

Valve insert: AMETAL®

Valve plug: AMETAL® and PTFE

Spindle: Stainless steel

Spindle seal: EPDM O-ring

Δp insert: PPS

Membrane: EPDM

Springs: Stainless steel

O-rings: EPDM

DN 65-200:

Valve body: Ductile iron EN-GJS-400-15

Valve insert: Ductile iron ENGJS-400-15 and brass

Valve plug: Stainless steel and EPDM O-ring

Valve seat: Aluminium bronze

Spindle: Stainless steel

Spindle seal: EPDM

Δp insert: Ductile iron EN-GJS-400-15, stainless steel and brass.

Membrane: Reinforced EPDM,  DN 200 EPDM

Springs: Stainless steel

O-rings: EPDM

AMETAL® is the dezincification resistant alloy of IMI.

Surface treatment

DN 10-50: Non treated

DN 65-200: Electrophoretic painting

Certifications and directives

EAC

*) Notified body.

CE 0409*: PN 25 DN 150-200.

CE: PN 16 DN 65-200, PN 25 DN 65-125.

The table below assists you in finding the relevant product based on its variant. For more details, please download the datasheet above.

Related products