Skip to main content
Vento Connect

Vento Connect

For heating, solar, and chilled water systems

Vento Connect is a cyclonic vacuum degasser for heating and solar systems, and chilled water systems. Its use is particularly recommended where high performance, compact design and precision are required. The industrial version VI is especially designed for high pressure applications up to 20.5 bar. The new BrainCube Connect control panel allows a new level of connectivity, enabling communication with the BMS system, other BrainCubes as well as remote operation of the pressurisation system through live viewing.

Technical SpecificationsAccessories_EN_low.pdf
Technical SpecificationsPlanning_and_Calculation_EN_low.pdf
Technical SpecificationsVento_Connect_EN_low.pdf

Product branding

imi_pneumatex

Features and Benefits

Higher Efficiency Cyclonic vacuum degassing

Significantly higher efficiency than most other vacuum degassing systems.

Direct degassing of make-up water

For additional protection against corrosion.

Easy Commissioning, Remote Access and Trouble-shooting

Integrated standard connections to our IMI Webserver and to BMS.

Vento Compact

Compact design for floor and wall hanging installation

Optional sound absorbing wall bracket

For Vento Compact in installations particularly sensitive to structure-borne sound.

Full range

Serving installations from 0,5 - 20,5 bar

Applications

For systems according to EN 12828, SWKI HE301-01, EN 12976, ENV 12977, EN 12952, EN 12953

Heating, solar and chilled water systems.

Pressure

Max. admissible pressure, PS: see Articles

Min. admissible pressure, PSmin: -1 bar

Temperature

Max. admissible temperature, TS: 90°C

Min. admissible temperature, TSmin: +5 °C

Media

Ethylene or propylene glycol-based antifreeze up to 50%.

Non-aggressive and non-toxic system media.

Supply voltage [V]

1 x 230 V (± 10 %) / 50 Hz

Transportation and storage

In frostless, dry places

Standard

Constructed according to MD 2006/42/EC, Annex II 1.A EMC-D. 2014/30/EU

Mechanical connections

Sin1: inlet from the system G1/2"

Sout: outlet to the system G1/2"

Sin1: inlet from the system G3/4"

Sout: outlet to the system G3/4"

Swm: inlet water make-up G3/4"

Electrical connection

Electrical connections:

Onsite fuses according to power demand and local norms
4 (V/VI) or 3 (VF) potential-free outputs (NO) for external alarm indication (230V max. 2A)
1 RS 485 In/Output
1 Ethernet RJ45 plug socket
1 USB Hub plug socket

Material

Material:

Metal components with medium contact: carbon steel, cast iron, stainless steel, AMETAL®, brass, gunmetal.

Enclosure class

IP54 according to EN 60529

The table below assists you in finding the relevant product based on its variant. For more details, please download the datasheet above.