Skip to main content

TA-Smart: Bringing data to life

TA-Smart is a connected control valve with measurement capabilities providing best in class control performance, energy savings, seamless installation and commissioning.

ta smart hero

A game-changing 2-in-1 solution

Balancing & control function dynamically compensates for pressure fluctuations providing optimum room comfort and high energy efficiency under all conditions.

Continuous measurement of flow, valve position, temperature difference and power with outstanding accuracy in water / water-glycol mixtures over a wide range of temperatures and pressures.
 

Key Features

ta smart control and measures

Controls & Measures

Market-leading control performance, from 0.5% to 100% of qnom, thanks to great valve controllability and fast response time. Highly accurate flow measurement with ultrasonic technology, even in low flow conditions and in water-glycol mixtures. 

Did you know?
HVAC systems operate 80% of the time at less than 50% of their design load, which is less than 20% of flow. TA-Smart's great control and measurement capability at low flow rates allows you to achieve optimal indoor comfort all year-round.

ta smart continous data

Logs Real-Time & Continuous Data Points

Continuous local or cloud data logging of key circuit parameters: flow, valve position, temperature difference, power and fluid content, through a versatility of communication modes, both digital and analog.

  Smarter building performance

Smarter Building Performance

Measuring is knowing. Seamless accessibility to critical circuit parameters and valve configuration information directly via your smartphone, even without BUS communication. Eliminate system opacity, reduce operating costs and enable better troubleshooting and optimization.

TA-Sense Dp product

TA-Smart-Dp and TA-Sense-Dp: Differential Pressure Control Made Smart​

Maintain stable differential pressure while unlocking real-time data insights for optimised energy use and operational transparency. ​

  • Capillary-free
  • Visibility of static pressure​
  • IP65-rated sensor​
  • Broad pressure range coverage
energy saving

HyCloud

Get Connected to Your TA-Smart Valves

  • Use HyCloud to get an overview of how your system is performing
  • Easy access to the data
  • Create projects where you can share the data with your colleagues and stakeholders
  • Highest level of data security
TA-Smart Graphic

Convenient Installation

Compact valve size allows for seamless mounting capabilities even in retrofit applications. 

TA-Smart is now available with factory pre-mounted connection cables.

✓ Compact valve that easily fits in retrofit applications.
✓ Fast installation thanks to pre-mounted cables.
✓ Built-in measurement capabilities.

  Smarter building performance

Outstanding mechatronic engineering

Valve entirely developed in-house by R&D teams to achieve best in class control performance mastering both energy meter technology and leveraging expertise on control valves.

Benefits at Every Stage

Keynote