Skip to main content
Dynacon Eclipse

Dynacon Eclipse

Floor heating manifold with automatic flow control

Dynacon Eclipse adjusts the flow rate in the individual heating circuits directly in l/h. This means hydraulic balancing is achieved in one simple operation. The set flow rate is constantly adapted, i.e. if the rate becomes too high, e.g. due to closing adjacent circuits, Dynacon Eclipse controls the flow automatically to the set value. The control cartridge always ensures a constant flow. This makes Dynacon Eclipse heating circuit manifolds a time and cost-saving solution especially for system commissioning.

Technical SpecificationsDynacon-Eclipse_EN_lq.pdf

Product branding

imi_heimeier

Features and Benefits

Automatic hydraulic balancing
Due to integrated flow controller inside each thermostatic insert

Flow indicator for each heating circuit
For functional check

Manifold made of stainless steel
Corrosion-resistant, durable and safe

Time and cost-saving commissioning solution

Applications

Floor heating systems

Functions

Draining

Filling

Flow limitation

Shut-off

Flushing

Individual room temperature control with actuator or thermostatic head with remote dial<

Venting

Pressure class [PN]

PN 6

Differential pressure (ΔpV)

Max. differential pressure:

60 kPa (<30 dB(A))

Min. differential pressure:

30 – 150 l/h = 17 kPa

150 – 300 l/h = 25 kPa

Flow range

The flow can be stepless pre-set within the range: 0.132 – 1.321 gpm.

Delivery setting: Commissioning setting.

Max. 2,5 m3/h per heating circuit manifold.

Temperature

Max. working temperature: 70°C

Min. working temperature: -5°C

Manifold boxes

Manifold boxes available as flush-mounted version.

Marking

IMI Heimeier

Orange protection cap.

Connection kits

The following manifold connection kits are available:

- Connection kit 1 with Globo ball valves.

- Connection kit 2 with STAD balancing valve and Globo ball valve.

- Connection kit 3 with Zeparo Vent air separator in supply pipe and Zeparo Dirt sludge separator in return.

- Connection kit 4 with Globo ball valve, including spacer for heat meter in return and Globo ball valve with connection for direct measurement in supply and return pipe.

- Connection kit 5 fixed value control station with high-efficiency pump for controlling the supply temperature.

- Connection kit with ball valves, straight connection, including spacer for heat meter in return.

- Connection kit with ball valves, angle connection, including spacer for heat meter in return.

- Thermostatic mixing valve for radiant heating. Pump connection with ball valve.

Connection to thermostatic head and actuator

IMI Heimeier M30x1,5

Material

Manifold:
Stainless steel 1.4301
Connection fittings: Nickel-plated brass.

Thermostatic insert:
Brass
O-rings: EPDM
Valve disc: EPDM
Spring: stainless steel
Thermostatic insert: Brass, PPS (polyphenylsulphide) and SPS (syndiotactic polystyrene)
Spindle: Niro-steel spindle with double O-ring seal.

Flow meter:
Heat-resistant plastic and stainless steel. Brass. EPDM seals.

Filling, draining, flushing and venting device:
Nickel-plated brass and plastic. EPDM seals.

The table below assists you in finding the relevant product based on its variant. For more details, please download the datasheet above.