TA-Slider 500 BACnet/Modbus

TA-Slider 500 BACnet/Modbus

Digitally configurable proportional push-pull actuator for Bus communication with BACnet MS/TP or Modbus RTU – 112/67 lbf (500/300 N)

Digitally configurable actuators for Bus communication with BACnet MS/TP or Modbus RTU, and a wide range of setup options provide extensive flexibility for on-site parameter adaptation. Fully programmable binary input, relay and adjustable maximum stroke of the valve bring new opportunities for advanced hydronic control and balancing.

Technical SpecificationsTA-Slider_500_BACnet_Modbus_US_low.pdf
Technical SpecificationsTA-Slider_160_BACnet_Modbus_US_low.pdf
Technical SpecificationsTA-Slider_500_BACnet_Modbus_EN_low.pdf

Features and Benefits

Convenient, reliable setup

Fully customisable by smartphone via Bluetooth using a TA-Dongle.

Fully configurable

More than 200 setup options allow input and output signals, binary input, relay, characteristics and many other parameters to be configured.

Easy diagnostics

Tracks the last 10 errors to allow system faults to be found quickly.

Quick copying of settings

Setup configuration can be copied quickly from the TA-Dongle to identical TA-Slider actuators.

Noise level

Max. 30 dBA

Supply voltage [V]

24 VAC/VDC ±15%. Frequency 50/60 Hz ±3 Hz

Connection to valve

Swivelling nut M30x1,5

Ingress protection

IP54 all directions (according to EN 60529)

Temperature

Media temperature: max. 248°F

Operating environment: 32°F to 122°F (5-95%RH, non-condensing)

Storage environment: -4°F to 158°F (5-95%RH, non-condensing)

Input signal

0(2)-10 VDC, Ri 47 kΩ.

0.33 Hz low pass filter.

Adjustable hysteresis sensitivity 0.1-0.5 VDC.

By BACnet/Modbus or with hybrid control mode

Default setting: By BACnet/Modbus. If Hybrid mode chosen, default input signal is Proportional 0-10 VDC.

Proportional: 0-10, 10-0, 2-10 or 10-2 VDC.

Proportional dual-range (for change-over): 0-3.3 / 6.7-10 VDC, 2-4.7 / 7.3-10 VDC, 0-4.5 / 5.5-10 VDC or 2-5.5 / 6.5-10 VDC.

Proportional split-range: 0-5, 5-0, 5-10 or 10-5 VDC; 0-4.5, 4.5-0, 5.5-10 or 10-5.5 VDC; 2-6, 6-2, 6-10 or 10-6 VDC.

Control speed

101.6 or 154 s/in (4 or 6 s/mm).

Default setting: 101.6 s/in (4 s/mm).

Output signal

BACnet/Modbus

Adjusting force

Pull 67 lbf (300 N)

Push 112 lbf (500 N)

Protection class

III (SELV)

(according to EN 61140)

Stroke

0.64 in (16.2 mm)

Automatic detection of the valve lift (stroke detection)

Certifications and directives

EMC-D. 2014/30/EU: EN 60730-1, -2-14.

LV-D. 2014/35/EU: EN 60730-1, -2-14.

RoHS-D. 2011/65/EU: EN 63000

Cable

Separate overmoulded cables (see Additional equipment).

Type LiYCY 5x22 AWG (5x0.34 mm2) (cables A and B) and type LiYY 6x22 AWG (6x0.34 mm2) (cable C).

Halogen free, fire class B2ca – s1a, d1, a1 according to EN 50575.

Relay cable (R24 version):

Type LiYY 3x22 AWG (3x0.34 mm2).

3.28 ft, 6.56 ft or 16.4 ft. With wire end sleeves.

Halogen free, fire class B2ca – s1a, d1, a1 according to EN 50575.

Colour

White RAL 9016, grey RAL 7047.

Marking

Label: IMI TA, CE, product name, article No. and technical specification.


Material

Cover: PC/ABS GF8

Housing: PA GF40.

Swivelling nut: Nickel-plated brass.

Power consumption

Operation: < 3.0 VA (VAC); < 1.5 W (VDC)

Standby: < 1.5 VA (VAC); < 0.75 W (VDC)