Bringing DATA to life
TA-Smart is a connected control valve with measurement capabilities providing best in class control performance, energy savings, seamless installation and commissioning.

A game-changing 2-in-1 solution
Balancing & control function dynamically compensates for pressure fluctuations providing optimum room comfort and high energy efficiency under all conditions.
Continuous measurement of flow, valve position, temperature difference and power with outstanding accuracy in water / water-glycol mixtures over a wide range of temperatures and pressures.
Key features

Controls & Measures
Market-leading control performance, from 0.5% to 100% of qnom, thanks to great valve controllability and fast response time. Highly accurate flow measurement with ultrasonic technology, even in low flow conditions and in water-glycol mixtures.
Did you know?
HVAC systems operate 80% of the time at less than 50% of their design load, which is less than 20% of flow. TA-Smart's great control and measurement capability at low flow rates allows you to achieve optimal indoor comfort all year-round.

Logs real-time & Continuous data points
Continuous local or cloud data logging of key circuit parameters: flow, valve position, temperature difference, power and fluid content, through a versatility of communication modes, both digital and analog.

Smarter building performance
Measuring is knowing. Seamless accessibility to critical circuit parameters and valve configuration information directly via your smartphone, even without BUS communication. Eliminate system opacity, reduce operating costs and enable better troubleshooting and optimization.

HyCloud
Get connected to your TA-Smart valves
- Use HyCloud to get an overview of how your system is performing
- Easy access to the data
- Create projects where you can share the data with your colleagues and stakeholders
- Highest level of data security

HyCloud
Get connected to your TA-Smart valves
- Use HyCloud to get an overview of how your system is performing
- Easy access to the data
- Create projects where you can share the data with your colleagues and stakeholders
- Highest level of data security

Convenient Installation
Compact valve size - up to 80% smaller than competitor products - allows for seamless mounting capabilities even in retrofit applications. This 2-in-1 solution removes the need to install additional devices to fulfill measurement requirements from regulations and certifications.

Outstanding mechatronic engineering
Valve entirely developed in-house by R&D teams to achieve best in class control performance mastering both energy meter technology and leveraging expertise on control valves.
Benefits at every stage
Products
Keynote



